Geoelectric Data Retrieval Mechanism

Soil investigations using the Geoelectric Method are carried out using certain types of measurement paths. The length of each track is 120 meters with the initial space (a) being 4 meters. The configuration used in this measurement is the Wenner-Alfa type.

Current (I) originating from the dry battery will be injected into the ground through electrodes A and B. Previously, this current had gone through a strengthening process carried out by the inverter component in the resistivity meter. From this injection, a voltage response (V) will occur coming from the soil/rock layer at the investigation location. This response is then read by a resistivity meter via electrodes M and N.